S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1yeas
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Fast Delivery
The supplier can deliver the goods within 15 days
Low MOQ
The MOQ for the supplier's products is 1
Full Customization
The supplier provides full customization services
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (26)
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
  • S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak Analyzer
Find Similar Products

Basic Info.

Model NO.
S400-W
Brand
Zhongan
Customized
Customized
Portable
Non Portable
Certification
FCC, CE, RoHS
Type
Electrochemical Gas Analyzer
Detected Gas
Combustible Gas, Oxygen and Toxic Gas
Sampling Method
Natural Diffusion Type
Detection Principle
Catalytic Combustion Type, Electrochemical Type, I
Resolution
1%Lel; 1ppm/0.1ppm
Display Method
LCD Liquid Crystal Display, LED Digital Display
Transport Package
Flight Case
Trademark
ZhongAn
Origin
China
Production Capacity
50000pieces/Year

Product Description

S400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerS400-W Fixed Gas Detector Battery Type Combustible Gas Detector Point Type Chemical Plant Leak AnalyzerDescription

     The instrument adopts detector with high performance detection components and computer microcontrol technology, combined with advanced full-automatic mounting process, the product has the functions of on-site buzzer indicating sound, on-site flashing indicator light, and real-time display the gas concentration on monitoring site.
     The multi-function point type gas detector can convert the gas concentration signal in the air into electrical signal and remote transmission. It can adopt wireless transmission, GPRS transmission, RS485 and other transmission modes.
     Point gas detectors can be used in chemical plant areas, smelting and papermaking, refrigeration and fire fighting, gas catering, rubber, sewage treatment, pharmaceutical casting, petroleum refining, mining power, fire-fighting municipal, communications and other industrial environments that need to prevent explosion, poisoning and suffocation.

Functions Features

  • Sound and light integrated alarm
  • Accurate measurement
  • The sensor adopts imported gas sensitive components with high precision and small zero drift.
  • Explosion-proof design
  • It can be used in the dangerous situation of zone 1 and zone 2 under factory conditions
  • Wireless remote control technology
  • Natural diffusion detection
  • English LCD display
  • Two sets of switching signals
 
  • Double cavity structure

Technical Parameters

Detected Gas Combustible gas, oxygen and toxic gas
Sampling Method Natural diffusion type
Detection Principle Catalytic combustion type, electrochemical type, infrared, PID, etc.
Detection Range (0 - 100)%LEL; 0 - ****PPM
Resolution 1%LEL; 1PPM/0.1PPM
Display Method LCD liquid crystal display, LED digital display
Transmission Method LoRa wireless transmission (optional)
Power Supply Battery powered (built-in lithium battery)
Response Time T90 < 30s (combustible); T90 < 60s (toxic)
Explosion-proof Type Flameproof + Intrinsic Safety
Working Environment Temperature: -40ºC - 70ºC(combustible gas);  -40ºC - 70ºC(toxic gases)
Relative humidity ≤95%RH
Environmental Pressure (86 - 106)KPa
Working Duration Combustible/Infrared: 15 days (under normal working conditions); Toxic gas, Oxygen: 30 days (under normal working conditions)
Single Charging Duration 48 hours

 

Common Gas Parameter listing
Gas detected Measuring Range Optional Range Resolution Rat Response Time
LEL -combustible gas 0-100%LEL 0-100%VOL(Infrared or catalytic ) 1%LEL/1%vol ≤10s
 carbon monoxide 0-1000PPm 0-500/2000/5000PPm 0.1/1PPm ≤10s
TVOC 0-100PPM 0-100PPM 0.1PPm/1PPM ≤15s
hydrogen 0-100%LEL 0-1000PPM 1%LEL/1PPM ≤15s
natural gas 0-100%LEL 0-100%LEL 1%LEL ≤10s
Oxygen-O2 0-30%VOL 0-30%,0-100%VOL 0.1%vol ≤10s
ozone 0-10PPm 0-20,100PPm 0.01PPm/0.1PPM ≤15s
hydrogen sulfide-H2S 0-100PPm 0-50,200,1000PPm 1/0.1PPm ≤10s
Methane-CH4 0-100%LEL 0-100%VOL 1%LEL/1%vol ≤10s
fluorine 0-10PM 0-1,10PPM 1/0.1PPm ≤15s
hydrogen chloride 0-20PPm 0-20/50PPm/100PPM 0.01/0.1PPm ≤15s
Nitrogen-N2 0-30%VOL 0-30%VOL,100%VOL 0.1%LEL/1PPM ≤10s
hydrogen 0-100%LEL 0-1000PPm 1%LEL/0.1PPm ≤15s
chlorine 0-20PPm 0-10,100PPm 0.1PPm ≤15s
ammonia gas 0-100PPm 0-50,500,1000PPm 1/0.1PPm ≤15s
oxynitride 0-20PPm 0-50,1000PPm 0.1/1PPm ≤15s
methanal 0-20PPm 0-50,100PPm 1/0.1PPm ≤15s
sulfur dioxide 0-20PPm 0-50,1000PPm 0.1/1PPm ≤15s
nitric oxide 0-250PPm 0-500,1000PPm 1PPm ≤15s
nitrogen dioxide 0-20PPm 0-50,1000PPm 0.1/1PPm ≤15s
 phosphine 0-20PPm 0-20,100PPm 0.1PPm ≤15s
acrylonitrile 0-100PPM 0-100PPm 0.1/1PPm ≤15s
carbon dioxide 0-5000PPm 0-1%/5%/10%VOL(Infrared ) 1PPM/0.01%VOL ≤15s
hydrogen fluoride 0-10PPm 0-1,10,50,100PPM 0.01/0.1PPm ≤15s
Xylene/methylbenzene 0-20PPm 0-5,10,50,100PPm 0.01/0.1PPm ≤15s
oxirane 0-100PPm 0-100PPm 1/0.1PPm ≤15s
For other gases and measuring ranges, please contact us directly!
 